CE3X Program before the new Basic Document DB-HE

ce3x program not updating

The CE3X Program is not updated before the new Basic Document DB-HE of the Technical Code that was approved September 2013.

We have to keep in mind that throughout this time and especially since September 2013, there have been Document updates Basic DB-HE of the Technical Code of the Building in points that we saw that possibly affect the certification process energy without any changes in the approved certification programs. This situation caused and has provoked a multitude of debates on the possible corrections that should have been made in the programs corresponding. As we have received an email from EFINOVATIC (Company made up of the team technician and director of the official procedure of energy certification of existing buildings CE3X) that clears up these doubts, we want to inform you in this post.

First, a timeline and access to articles from the Document updates Basic DB-HE and the new documents exposed for the Technical Code :

—————————————-

Content menu:

1.- The Document is renewed Basic DB-HE (Date September 2013)

The Ministry of Public Works published the order in the BOE FOM/1635/2013, of September 10, which updates the Basic Document DB-HE of the Technical Code of the building. Access to the article:…… HERE . Highlights:

TABLE ACCORDING TO REGULATIONS OF UPDATE:

thermal transmittance and permeability

TABLE ACCORDING TO DB HE PREVIOUS:

thermal transmittance and previous permeability

2.- Documents DA DB-HE 1 and DA DB-HE 2 (Date October 2013)

The supporting documents DA DB-HE 1 and DA DB-HE 2 to the basic document saving energy 2013 of the Technical Code of the Edification. Access to the article:….. HERE .

3.- Informative document and complementary to (Date December of 2013)

The Ministry of Public Works published a document informative where the news are analyzed incorporated into the Technical Code DB HE 2013 through questions and answers that helped us better understanding of new information and built-in requirements. Access to the article:

—————————————-

We leave you the email received by EFINOVATIC literally to clarify the doubts:

«As you surely know, last month of September, a modification of the Basic Document was approved DB-HE «Energy Saving». Among other things, this change implies an increase in the minimum efficiency requirements energy in building projects, and changes in the climatic zones, in the meteorological files and in the form to demonstrate compliance that will require new computer tools.

The application of this modification can be perform on a voluntary basis until next Thursday the 13th of March, at which time it will become mandatory.

Certification procedures Energy, from an administrative point of view, are independent of CTE verification procedures affected by this modification . For this reason, from this date, certification energy of buildings can continue to be carried out with the same procedures as employees until now .

In short, from this date you can continue using CE³X to certify properties existing ones , without any change in the way you use the program.”

We hope we have shed some light for those certifying technicians who have not received such information.

Explanatory note: After the different informative notes have been issued in this article both from the IDAE and from M. Fomento (Access to article HERE ). where inside a period of nine months from the entry into force of the new requirements of the DB-HE will proceed to its update.

# metal design, # fascia and gutter cleaning company, # new home builder, # tile sealant.